Audio-Technica
Audio-Technica AT4047/SV
Large dual-diaphragm cardioid condenser (DC bias), transformer-coupled output, with 80 Hz high-pass and 10 dB pad
Power Phantom 48 V DC.
- Type
- Condenser
- Pattern
- Cardioid
- Sensitivity
- −35 dBV/Pa
- Among 204 condensers: more output than 64%
- Among 311 mics: more output than 75%
- Self-noise
- 9 dB(A)
- Among 258 condensers: quieter than 86%
- Among 272 mics: quieter than 87%
- Max SPL
- 149 dB SPL
- Among 277 condensers: takes louder sound than 90%
- Among 343 mics: takes louder sound than 89%
- Rated range
- 20 – 18k Hz
vs 75 side-address condensers
More output than 55% of 75 side-address condensers.
Each stripe is one side-address condenser with a published sensitivity, and each bar counts them; further right means more output. This mic is in blue.
vs 99 side-address condensers
Quieter than 69% of 99 side-address condensers.
Each stripe is one side-address condenser with a published self-noise, and each bar counts them; further right means quieter. This mic is in blue.
vs 107 side-address condensers
Takes louder sound than 92% of 107 side-address condensers.
Each stripe is one side-address condenser with a published max SPL, and each bar counts them; further right means it takes louder sound. This mic is in blue.
Instruments sources recommend it for most
3 of 4; all under Recommended for.
Proximity effect: the bass it gains up close
From the spec sheet, p. 2.
Printed under the graph: "12\" or more on axis" (30 cm or more). Room and smoothing not stated.
Dashed: outside the rated range, or simulated (other angles and distances). Hover or tap the graphs for values.
Polar pattern
From the spec sheet, p. 2.
Full circle, 0° at the top, 5 dB per division. Measuring conditions not stated.
In practice
All specs
| From the spec sheet | ||
|---|---|---|
| Capsule | large dual-diaphragm; nickel-plated brass element baffle"Dual-diaphragm capsule design maintains precise polar pattern definition across the full frequency range"; "Precision-machined, nickel-plated brass, acoustic element baffle". | p. 1 |
| Sensitivity | −35 dBV/Pa (17.7 mV/Pa)open circuit. "–35 dB (17.7 mV) dB re 1V at 1 Pa" (sic). | p. 2 |
| Self-noise | 9 dB(A)typical, A-weighted (Audio Precision System One). "9 dB SPL", footnote "Typical, A-weighted, using Audio Precision System One". | |
| Max SPL | 149 dB SPL1 kHz, 1% THD; also 159 dB SPL, with 10 dB pad (nominal) | |
| Signal-to-noise ratio | 85 dB1 kHz at 1 Pa; typical, A-weighted | |
| Dynamic range | 140 dB1 kHz at max SPL, typical | |
| Output impedance | 250 ohmLow impedance balanced (page 1). | |
| Rated frequency range | 20 Hz to 18 kHzTolerance not stated. | |
| Powering | phantom 48 V DC"48V DC, 3.0 mA typical". | |
| Current draw | 3 mAtypical | |
| Low cut | off, 80 Hz, 12 dB/octave; 80 Hz; 12 dB/octave; high-pass"80 Hz, 12 dB/octave"; switch "Flat, roll-off". | |
| Pad | −10 dB"10 dB pad (nominal)". | |
| Connector | XLR-3 male (integral)"Integral 3-pin XLRM-type". | |
| Weight | 410 g"410 g (14.5 oz)"; the 2002 leaflet says "less accessories". | |
| Dimensions | 53.4 × 170 mmMaximum body diameter × length: "170.0 mm (6.69") long, 53.4 mm (2.10") maximum body diameter". | |
| Supplied accessories | AT8449/SV shock mount for 5/8"-27 threaded stands; dust cover; protective carrying case | |
| Output stage | Transformer-coupled | p. 1 |
| Output | Low impedance balanced, pin 2 hot | |
| Angle of acceptance | 120° (uniform) | |
| Case style | R1 | p. 2 |
| Finish | Vintage silver-matte, on microphone and shock mount | p. 1 |
| Operating temperature | Avoid more than 43 °C (110 °F) for long periods, and very high humidity | |
Documents
- AT4047/SV Cardioid Condenser Side-Address Microphonespec sheet, 0001-0199-01
- AT4047/SV Cardioid Condenser Microphoneuser leaflet, P51459-EN
Copies kept by Mic Archive (manufacturers move and drop their documents), unchanged, with their original addresses. Each is © its publisher.
Recommended for