Mic Archive

Neumann

Neumann MCM KK 14

Miniature cardioid electret capsule head (12 mm) for Neumann's Miniature Clip Mic (MCM) system; on the MCM 100 XLR output stage it is the MCM 114

Power P48 via the MCM 100 output stage (48 V ± 4 V, IEC 61938); the KK 14 itself takes ≤ 10 V with Rfeed 20 kohm (wireless bodypacks).

Type
Condenser (electret)
Pattern
Cardioid
Sensitivity
−49 dBV/Pa
vs 16 clip-on condensers

More output than 40% of 16 clip-on condensers.

Each stripe is one clip-on condenser with a published sensitivity, and each bar counts them; further right means more output. This mic is in blue.

  • Among 204 condensers: more output than 10%
  • Among 311 mics: more output than 36%
Self-noise
23 dB(A)
vs 14 clip-on condensers

Quieter than 69% of 14 clip-on condensers.

Each stripe is one clip-on condenser with a published self-noise, and each bar counts them; further right means quieter. This mic is in blue.

  • Among 258 condensers: quieter than 13%
  • Among 272 mics: quieter than 12%
Max SPL
153 dB SPL
vs 16 clip-on condensers

Takes louder sound than 73% of 16 clip-on condensers.

Each stripe is one clip-on condenser with a published max SPL, and each bar counts them; further right means it takes louder sound. This mic is in blue.

  • Among 277 condensers: takes louder sound than 96%
  • Among 343 mics: takes louder sound than 95%
Rated range
20 – 20k Hz

Frequency response

Instruments sources recommend it for most
Angle

Distance

From the quick guide, p. 2.

All specs

From the quick guide
Specifications table, MCM 114 column (KK 14 with MCM 100).
Capsulepressure-gradient electret capsule, Ø 12 mm head"Acoustic operating principle: Pressure gradient transducer"; KK 14 "Ø 12 mm x 12 mm".p. 1
Sensitivity−49 dBV/Pa (3.6 mV/Pa)1 kHz into 1 kohm, ±2 dB. "3.6 mV/Pa -49 dBV ± 2 dB".
Self-noise23 dB(A)IEC 61672-1 A-weighting, RMS. "23 dB-A".
Self-noiseCCIR 46834 dBCCIR 468-3, quasi peak.
Max SPL153 dB SPLTHD < 0.5%, with MCM 100 (supply 10 V, Rfeed 20 kohm); also 147 dB SPL, THD < 0.5%, supply 5 V, Rfeed 8.25 kohm. Footnote 2: "THD of microphone amplifier at an input voltage equivalent to the capsule output at the specified SPL".
Signal-to-noise ratio71 dBre 94 dB SPL, A-weighted; also 60 dB, re 94 dB SPL, CCIR.
Dynamic range130 dBof the amplifier, A-weighted, THD < 0.5%.
Output impedance50 ohmrated, MCM 100 output; also 10 ohm, KK 14 alone. "KK 14: 10 Ω | MCM 100: 50 Ω".
Rated load impedance1000 ohmrated.
Rated frequency range20 Hz to 20 kHz
PoweringP48 via the MCM 100 output stage (48 V ± 4 V, IEC 61938); the KK 14 itself takes ≤ 10 V with Rfeed 20 kohm (wireless bodypacks)
Current draw3.5 mAMCM 100; also 0.22 mA, KK 14 alone. "KK 14: 0.22 mA | MCM 100: 3.5 mA".
ConnectorXLR-3 on the MCM 100 output stage; 3.5 mm mini jack between capsule cable and MCM 100"Required connector: XLR 3F" (the mating cable socket). The 1.8 m AC 31 mini-jack cable links the gooseneck to the MCM 100 (p. 2).
Weight2.3 gKK 14 capsule head. "KK 14: 2.3 g | MCM 100: 39,2 g".
Dimensions12 × 12 mmKK 14 diameter × length "Ø 12 mm x 12 mm". The MCM 100 is Ø 22 mm × 77 mm.
MCM 100 output stageXLR output stage (mini jack in, XLR out): 50 Ω, P48, 3.5 mA, 39.2 g, Ø 22 × 77 mm
MCM 102 output stageLEMO / XLR output stage (works with the AC 32 cable only); not in the specifications tablep. 2
GoosenecksSH 100: 144 mm, 16 g; SH 150: 194 mm, 20 g; SH 250: 294 mm, 30 g (overall length, weight)p. 1
CablesAC 31 mini jack (0.6, 1.8, 3.0 m); AC 32 LEMO 3-pin, AC 33 MicroDot, AC 34 mini XLR 4-pin (0.6, 1.8, 3.0 m) for bodypack transmitters
ClipsMC 1 high strings (violin, viola, mandolin; 32-50 mm), MC 2 cello, MC 3 double bass strings, MC 4 double bass rib, MC 5 universal strap (woodwinds, harp; 10-80 mm), MC 6 universal clamp (brass, sax, percussion, stands; 0-20 mm), MC 7 drum rims, MC 8 magnetic piano clip, MC 9 guitar (85-132 mm)
SetsMCM 114 set high strings, cello, bass, woodwinds, guitar, brass/sax/uni, drums, and stereo set piano
WindscreenWS 110 MCM windscreen soft
Other capsule headsKK 13 omni and KK 15 supercardioid (sold individually)
Operating conditions0 to 40 °C, 0-90 % humidity (storage -20 to 70 °C, 0-95 %)

Documents

Copies kept by Mic Archive (manufacturers move and drop their documents), unchanged, with their original addresses. Each is © its publisher.

Other mics

More from Neumann

All 35 Neumann mics

Other cardioid condenser mics

All 419 mics