Mic Archive

Neumann

Neumann U 67

Large-diaphragm tube condenser (EF 86), omni, cardioid and figure-8; discontinued (the specs here are for the 1992 reissue)

Approximate Some readings for this mic are uncertain; see the graphs.

Power NU 67 A power supply (plate +210 V, heater -6.3 V).

Type
Condenser
Pattern
Switchable, 3OmniCardioidFigure-8
Sensitivity
−32.4 dBV/Pa computed
Self-noise
17 dB(A)
vs 99 side-address condensers

Quieter than 20% of 99 side-address condensers.

Each stripe is one side-address condenser with a published self-noise, and each bar counts them; further right means quieter. This mic is in blue.

  • Among 258 condensers: quieter than 40%
  • Among 272 mics: quieter than 41%
Max SPL
114 dB SPL
vs 107 side-address condensers

Takes louder sound than 4% of 107 side-address condensers.

Each stripe is one side-address condenser with a published max SPL, and each bar counts them; further right means it takes louder sound. This mic is in blue.

  • Among 277 condensers: takes louder sound than 2%
  • Among 343 mics: takes louder sound than 1%
Rated range
20 – 20k Hz
Released
1960

Frequency response

Instruments sources recommend it for most

5 of 8; all under Recommended for.

Angle

Distance

From the manual 1992 rh, p. 6.

Polar pattern

Transparency

From the manual 1992 rh, p. 7. Approximate

All specs

From the manual 1992 rh
Values per pattern are printed as omni/cardioid/figure-8; the cardioid value is the main one here.
Capsulepressure-gradient transducer, large dual diaphragmp. 5
Sensitivity−32.4 dBV/Pa (24 mV/Pa)cardioid, 1 kHz into 1 kohm; ±1 dB; also −36.5 dBV/Pa, omni; also −35.9 dBV/Pa, figure-8. Not stated by the manufacturer: Printed as 15/24/16 mV/Pa; converted with 20·log10(mV/1000).
Self-noise17 dB(A)cardioid; DIN/IEC 651; also 21 dB(A), omni; also 20 dB(A), figure-8.
Self-noiseCCIR 46828 dBcardioid; DIN 45 590 / DIN 45 405, CCIR 468-3; also 32 dB, omni; also 31 dB, figure-8.
Max SPL114 dB SPLless than 0.5% THD; also 124 dB SPL, with pre-attenuation. THD of the amplifier at an input equal to the capsule output at that SPL; max. output voltage 250 mV each.
Signal-to-noise ratio66 dBcardioid; re 1 Pa at 1 kHz, CCIR 468-3; also 62 dB, omni; also 63 dB, figure-8.
Output impedance200 ohm
Rated load impedance1000 ohm
Rated frequency range20 Hz to 20 kHz
PoweringNU 67 A power supply (plate +210 V, heater -6.3 V)Plate +210 V ± 2%, ≤ 1 mA; heater -6.3 V ± 2%, ≤ 200 mA.
Weight560 g
Dimensions56 × 201 mmDiameter × length.
Noiseold standard28/25/28 dB (DIN 45 405, valid until 1983), omni/cardioid/figure-8
TubePentode EF 86, selected; warm-up about 1 minute; runs at about 45 °C
From the Recording Hacks page
Released1960

Documents

Copies kept by Mic Archive (manufacturers move and drop their documents). Each is © Neumann, unchanged, with its original address.

Other mics

More from Neumann

All 35 Neumann mics

Other omni / cardioid / figure-8 condenser mics

All 419 mics