Neumann
Neumann M 49 V
Tube (valve) condenser, large dual-diaphragm (K 47/49), pattern continuously variable from omni through cardioid to figure-8 by remote control; the 2022 re-edition of the M 49
Power NM V pattern control unit (mains, 100-120 V / 220-240 V AC, switched automatically).
- Type
- Condenser
- Pattern
- Switchable, 5
- Sensitivity
- −42 dBV/Pa
- Among 204 condensers: more output than 25%
- Among 311 mics: more output than 47%
- Self-noise
- 20 dB(A)
- Among 258 condensers: quieter than 23%
- Among 272 mics: quieter than 23%
- Max SPL
- 125 dB SPL
- Among 277 condensers: takes louder sound than 10%
- Among 343 mics: takes louder sound than 8%
- Rated range
- 40 – 16k Hz
vs 75 side-address condensers
More output than 5% of 75 side-address condensers.
Each stripe is one side-address condenser with a published sensitivity, and each bar counts them; further right means more output. This mic is in blue.
vs 99 side-address condensers
Quieter than 5% of 99 side-address condensers.
Each stripe is one side-address condenser with a published self-noise, and each bar counts them; further right means quieter. This mic is in blue.
vs 107 side-address condensers
Takes louder sound than 13% of 107 side-address condensers.
Each stripe is one side-address condenser with a published max SPL, and each bar counts them; further right means it takes louder sound. This mic is in blue.
Proximity effect: the bass it gains up close
From the manual, p. 8.
Free field, IEC 60268-4, tolerance ±2 dB (as printed); relative dB. The legend gives one line for "Fernfeld / Far field + Nahfeld / Near field 20 cm".
Dashed: outside the rated range, or simulated (other angles and distances). Hover or tap the graphs for values.
Polar pattern
From the manual, p. 8.
Free field, IEC 60268-4. 125 Hz to 1 kHz drawn on the left half, 2 to 16 kHz on the right; the pattern is taken as symmetric. 5 dB per ring, centre -25 dB.
In practice
All specs
| From the manual | ||
|---|---|---|
| Technical specifications (p. 12), "Omni/cardioid/figure-8" figures in that order. | ||
| Capsule | K 47/49, pressure-gradient dual-diaphragm transducer with two gold-vaporised membrane foils"The K 47/49 capsule, a pressure-gradient dual-diaphragm transducer with two gold-vaporized membrane foils" (p. 5). | p. 5 |
| Sensitivity | −42 dBV/Pa (8 mV/Pa)1 kHz into 1 kohm, cardioid; tolerance ±1 dB; also −43.5 dBV/Pa, omni; also −40 dBV/Pa, figure-8. "6.5/8/10 mV/Pa ≅ –43.5 /–42 /–40 dBV". 7, printed p. | p. 7 |
| Self-noise | 20 dB(A)cardioid; IEC 60268-1, A-weighting to IEC 61672-1, RMS; also 21 dB(A), omni; also 19 dB(A), figure-8. "21/20/19 dB-A". 7, printed p. | |
| Self-noiseCCIR 468 | 30 dBcardioid; CCIR 468-3, quasi peak; also 32 dB, omni; also 30 dB, figure-8. "32/30/30 dB". 7, printed p. | |
| Max SPL | 125 dB SPLTHD < 0.5%. THD of the microphone amplifier at an input voltage equivalent to the capsule output at that SPL (footnote 6). | |
| Signal-to-noise ratio | 74 dBcardioid, A-weighted, re 94 dB SPL; also 73 dB, omni, A-weighted; also 75 dB, figure-8, A-weighted; also 64 dB, cardioid, CCIR; also 62 dB, omni, CCIR; also 64 dB, figure-8, CCIR. A-weighted "73/74/75 dB", CCIR "62/64/64 dB". 7, printed p. | |
| Dynamic range | 105 dBamplifier, cardioid, A-weighted, THD < 0.5%. "Dynamic range of the amplifer (cardioid)". | |
| Output impedance | 200 ohmnominal | |
| Rated load impedance | 1000 ohmnominal | |
| Rated frequency range | 40 Hz to 16 kHz"Frequenzy response 40 Hz...16 kHz" (sic). | |
| Powering | NM V pattern control unit (mains, 100-120 V / 220-240 V AC, switched automatically)"Connect the microphone only to the included NM V pattern control unit" (p. 5); the NM V "automatically switches between the 100-120 V and 220-240 V ac mains voltage ranges" (p. 6). | p. 6 |
| Connector | 7-pin, to the NM V pattern control unit by the KC 5 cable; XLR-3 output on the NM VPin-out and cables on p. 6. | |
| Weight | 800 gapprox. | p. 7 |
| Dimensions | 80 × 163 mmDiameter 80 mm, length 163 mm. | |
| Supplied accessories | NM V pattern control unit; MZ 49 A elastic holder; KC 5 cable (10 m); mains cables (EU, UK, US); transport case"Delivery includes" and the description of the set (p. 5). | p. 5 |
| Tube | Selected triode; plate 120 V, ≤ 1 mA; heater 6.3 V, ≤ 200 mA; warm-up approx. 1 minute | p. 7 |
| Output transformer | BV 11, wound to the original specifications | p. 5 |
| Max. output voltage | –8 dBu | p. 7 |
| High-pass filter | Fixed, 30 Hz (–3 dB); lowered to 12 Hz with the internal switch S4 (set by Neumann service) | p. 5 |
| Cardioid-only mode | Internal switch S2 (set by Neumann service): pattern selector inactive, sensitivity ~2 dB higher, equivalent noise ~3 dB lower | |
| Remote pattern control | NM V pattern control unit: the pattern is set on the NM V and is continuously variable; an elevated noise floor for a few seconds after a change while the capsule recharges | |
| Cable length | 7-core cable to the NM V at most 50 m (else self-noise rises from a too low heater voltage); whole signal path at most 300 m | p. 6 |
| Operating conditions | 0 to +40 °C, 0-75% relative humidity (non-condensing); storage –20 to +70 °C, 0-95% | p. 7 |
| Older supplies | The NM V can power vintage Neumann mics with the AC 701 tube (older M 49, M 249); the old N 52 and NN 48 supplies cannot power the M 49 V | p. 6 |
| Selected accessories | MF 3/4/5 stands, STV 4/20/40/60 extensions, PS 15 and PS 20 a popscreens, WS 49 foam windscreen, IC 3 mt cable | p. 7 |
Documents
- M 49 V operating manualBedienungsanleitung / Operating Manual), Publ. 06/22 (592832/A01
- M 49 V / M 50 V operating manual, Publ. 02/25592832/A02
- M 49 - The First Remote ControllableNeumann historical collection, "General information about the M 49"
Copies kept by Mic Archive (manufacturers move and drop their documents), unchanged, with their original addresses. Each is © its publisher.
Recommended for